-40%
500 FT Spool Belden 9222-004500 Yellow Triaxial Cable RG-58A/U 50ohm 20AWG
$ 158.4
- Description
- Size Guide
Description
500FT Belden 9222 in pull out box.Product Description
50 Ohm Triax RG-58A/U Type, 20 AWG stranded (7x28) .037" tinned copper conductor, polyethylene insulation, double tinned copper braid shields (95%
coverage), PVC jacket.
Technical Specifications
Physical Characteristics (Overall)
Conductor
AWG Stranding Material Nominal Diameter No. of Coax
20 7x28 TC - Tinned Copper 0.038 in 1
Conductor Count: 1
Insulation
Material Nominal Diameter
PE - Polyethylene 0.12 in
Inner Shield Material
Type Layer Material Coverage [%]
Braid 1 Tinned Copper (TC) 95%
Inner Jacket Material
Material Nominal Diameter
PE - Polyethylene 0.177 in
Outer Shield Material
Type Layer Material Coverage [%]
Braid 1 Tinned Copper (TC) 95%
Outer Jacket Material
Material Nominal Diameter Nominal Wall Thickness
PVC - Polyvinyl Chloride 0.241 in 0.021 in
0.216 in
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR Nominal Inner Shield DCR Nominal Outer Shield DCR
9.5 Ohm/1000ft 4.7 Ohm/1000ft 4.3 Ohm/1000ft
Capacitance
Nom. Capacitance Conductor to Shield
30.8 pF/ft
Inductance
Nominal Inductance
0.077 μH/ft
Impedance
Nominal Characteristic Impedance
50 Ohm
High Frequency (Nominal/Typical)
Frequency [MHz] Nom. Insertion Loss
1 MHz 0.5 dB/100ft
10 MHz 1.5 dB/100ft
50 MHz 3.3 dB/100ft
100 MHz 4.9 dB/100ft
200 MHz 7.2 dB/100ft
400 MHz 12 dB/100ft
500 MHz 14 dB/100ft
700 MHz 18 dB/100ft
900 MHz 22 dB/100ft
1000 MHz 24 dB/100ft
Delay
Max. Delay Skew Nominal Velocity of Propagation (VP) [%]
66 ns/100m 66%
Voltage
Non-UL Voltage Rating
1400 V RMS
Temperature Range
Non-UL Temp Rating: 75°C
Operating Temp Range: -40°C To +75°C
Mechanical Characteristics
Bulk Cable Weight: 39 lbs/1000ft
Max. Pull Tension: 83 lbs
Min Bend Radius/Minor Axis: 2.5 in